/ Field knowledge · IMC 901.1–901.4
Chapter 9 does not operate by itself.
Before designing a specific appliance, identify the correct code path first. Gas-fired appliances are International Fuel Gas Code. Fireplaces and solid-fuel appliances are prohibited in hazardous locations and in Group I-2, Condition 2 occupancies. Original Masterbuild writing from Daily Code Talk #167.
Packet: 901 PDF · ES. Source: DCT #167. Kickoff: Chapter 9. 902: masonry. 903: factory-built. 904: pellet. 905: stoves.
- 901.1: Chapter 9 governs the appliances identified in the chapter, including factory-built fireplaces. Appearing in Chapter 9 does not make the IMC the complete path.
- 901.2: Chapter 9 applies in addition to the other applicable IMC requirements — location, installation, venting, listing.
- 901.3: fireplaces and solid-fuel-burning appliances are prohibited in hazardous locations.
- 901.4: solid-fuel-burning fireplaces and appliances are prohibited in Group I-2, Condition 2 occupancies.
Tool: Which Chapter 9 door?
Gas fireplace on the mechanical schedule with only an IMC 903 note
IFGC never opened. Occupancy is I-2. Two codes, one stove, no path.
What to send
Appliance type, fuel, occupancy, and whether the location is classified.
If the appliance is already on the schedule and the path is not
Send the cut sheet, the fuel, and the occupancy. Masterbuild will say whether Chapter 9 still has no row — not whether the AHJ will accept a substitution.