/ Field knowledge · IMC 905
905 is not the end of the chimney path.
Fireplace stoves: UL 737. Solid-fuel room heaters and fireplace inserts: UL 1482. Connecting to a chimney flue serving a fireplace must still comply with 801.7 and 801.10. Hearth extensions follow the stove listing; listed hearths UL 1618. New wood-burning residential hydronic heaters also need EPA certification. Daily Code Talk #171.
Packet: 905 PDF · ES. Source: DCT #171. Flue: 801.10. Dedicated: 801.11.
- Stoves, room heaters, and inserts are not interchangeable.
- 905.2 sends you back to Chapter 8. Do not stop at the listing sticker.
Insert specified as a “stove,” tied into a factory-built fireplace flue with no 801.10 listing
Wrong UL. Wrong flue. Wrong hearth.
What to send
Stove vs heater vs insert, the cut sheet, and how it connects to the flue.
If the appliance is already on the schedule and the path is not
Send the cut sheet, the fuel, and the occupancy. Masterbuild will say whether Chapter 9 still has no row — not whether the AHJ will accept a substitution.