/ Field knowledge · IMC 507.1 exceptions

A hood exception starts with the exact appliance and its evidence.

The 2024 model IMC 507.1 provides narrow paths for certain commercial kitchen equipment. A generic “listed” label does not waive a hood. First identify every appliance and its cooking process; then match each proposed path to the model-specific listing, installation instructions and required room ventilation or exhaust.

Educational reference to the 2024 model IMC. For permit work, confirm the locally adopted edition, amendments, appliance use and authority having jurisdiction (AHJ). This page does not determine whether a proposed lineup qualifies.

Potential paths to check, one appliance at a time

What the field answer should say

If the equipment schedule lacks the model, the qualifying listing or the ventilation calculation, the exception remains unverified. If an appliance under one hood requires Type I, the hood serving that lineup follows the Type I path under the applicable code. Calling a different hood “Type I” does not by itself resolve capture, grease duct, suppression, makeup air or installation requirements.

Common failure: a category in place of proof

“Recirculating,” “downdraft” or “electric” describes equipment; it does not prove that the exact tested configuration meets the proposed path. The UL 710B example is a complete system, while UL 197 requires the reduced-grease designation for the specific appliance.

Evidence to put on the drawings

References: ICC 2024 IMC Chapter 5 (model code) and UL's explanation of complete recirculating systems and reduced-grease listings. See the split field-tool screen, Daily Code Talk on 507.1, Type I hood requirements and domestic versus commercial cooking. Educational packet (PDF).

What to send

Send the menu and appliance lineup, model-specific listings and manuals, the proposed hood or integral system, the kitchen plan, and ventilation or exhaust calculation. Flag the exact path you want reviewed.

When the drawings claim “no hood required”

Run the exception screen and identify any missing evidence. MasterBuild can review the proposed path under a written scope; the AHJ decides permit acceptance.