/ Herramientas · Educativo

Empezar: empezar aquí. Mapa: conocimiento de campo. Las 48 pantallas completas están en field tools (inglés).

Ayudas que convierten una pregunta vaga en una mejor consulta.

No dimensionan equipos, no fijan la fecha de recertificación y no sustituyen el Código de Construcción de Florida adoptado ni al PE de registro.

Related working PDFs: Resources · Miami-Dade permit resources · FBC vs IMC · What to send. English: Field tools.

01 · IMC 505–508

Kitchen Type I / Type II pathfinder

The hood type follows the contaminant, not the room name. Pick the cooking that actually happens.

Educational classification against the model IMC. More: kitchen exhaust hub.

02 · IMC Table 403.3.1.1 (2024 model)

Outdoor-air occupancy estimator

Breathing-zone outdoor air Vbz = Rp × Pz + Ra × Az. This is not system outdoor air and not a 170 calculation.

Healthcare / I-2: ASHRAE 170 / IMC 407. Garages: use the 404 tool below. Free guide: Chapter 4 PDF.

03 · IMC 404 · Daily Code Talk #38

Enclosed-garage ventilation estimator

Full-On ≥ 0.75 cfm/sf. Automatic CO/NO₂ systems also need Standby ≥ 0.05 cfm/sf. Open-garage definitions are a building-code question, not this math.

04 · IMC Chapter 7 educational rates

Combustion-air method check

Method first, free area second. Direct-vent appliances follow the listing. Nominal louver size is not free area.

05 · IMC 508

Kitchen makeup-air equality check

Replacement air has to be approximately equal to exhaust and actually available when the hood is on. Transfer air is not a slogan.

06 · IMC 607

Fire / smoke damper pathfinder

The assembly type controls the damper. A typical that says “F/S where required” is why the comment exists.

07 · Plan-review triage

Comment classifier

Pick the kind of comment. Get the hub, the usual drawing miss, and what to send. Not a code opinion on your letter.

Library of typical wording: typical plan-review comments.

08 · Miami-Dade electrical recertification

Records pack — not a due-date calculator

Masterbuild does not invent your deadline. The notice does. This checklist builds the package any responsible electrical professional will ask for. Not the same process as Florida’s statewide structural milestone inspection — see electrical vs structural recertification.

Check what you already have

09 · IMC 401 vs 403 educational

Natural vs mechanical outdoor air

Chapter 4 is a method question before it is a cfm question. An operable window is not Table 403.

Educational. Healthcare / I-2 follows ASHRAE 170 / IMC 407. Garages follow IMC 404, not Table 403.

What to send, by job type

Full send-listEvery job type on one page Permit commentsLetter + current set + permit number Tenant improvementArchitectural TI set + existing MEP Kitchen / Type IPlan + equipment schedule + hood cuts Existing buildingPhotos of mechanical rooms, roof, panels Septic / OSTDSFolio, use, survey, intended footprint

Cuando la herramienta no basta

Si el resultado depende de sus planos, envíelos. El estimador termina donde empieza el encargo.

Enviar antecedentes

+1 (786) 398-6940  ·  osmany.portal@masterbuildconsulting.com

Masterbuild presta servicios de ingeniería bajo un alcance escrito. Nada en esta página es un dictamen de código para su proyecto.